Errata: Reference input not included in Figure 11.2 and dimensions of blocks are listed incorrectly
From FBSwiki
(Redirected from Errata: Reference input not included in Figure 11.2)
Return to Errata page |
Location: page 318, line -4 to -1
In Figure 11.2, the controller has input and output
, resulting in a 1x1 transfer function for
. The (generalized) process dynamics has outputs
and
and inputs
and
. So the proper dimension of the matrix transfer function
is 5 x 3.
The updated text should read
If we omit the reference input
, the system in Figure 11.1 can be captured by choosing
and
. The process transfer function
is a 5 x 3 matrix, and the controller transfer function
is a 1 x 1 matrix; compare with Exercise 11.3.
(Contributed by R. M. Murray, A. Aryanfar, 5 Jul 2011)