This pages lists all of the errata that apply to version 2.10c of Chapter 10 - PID Control. For a full list of errata, see the errata page.

Pages in category "PID Control errata v2.10c"

The following 4 pages are in this category, out of 4 total.

  • Errata: Caption for Figure 10.3b should be "Derivative action"
  • Errata: After equation (10.5), low frequency limit bound be 1/T d instead of T d
  • Errata: The b k i term in the characteristic polynomial has an extra factor of s
  • Errata: The PID integral time constant T i for the op amp implementation should be equal to R 2 C 2